5KW-14KW THREE PHSAE HYBRID INVERTER

5KW-14KW THREE PHSAE HYBRID INVERTER

5-14kW Rated AC Output Power ARC fault detection optional Support storing energy from diesel generator Support on/off grid mode switch, EPS output 20 PCS inverters parallel for off-grid operation Independent AC input port for diesel generator Colorful 7-inch touch LCD, IP65 protection degree Support different power inverters parallel connection Support battery charging/discharging according to the time setting 100% unbalanced output, each phase max. output up to 50% rated power

Solar Refrigerator & Freezer|Solar pump|solar power systems

Solar Refrigerator & Freezer|Solar pump|solar power systems

Solar Refrigerator & Freezer|Solar pump|solar power systems

Solar Refrigerator & Freezer|Solar pump|solar power systems

Technical Data


ModelMars-5G1-LEMars-6G1-LEMars-8G1-LEMars-10G1-LEMars-12G1-LEMars-14G1-LE
Battery Input
Battery Type Lead-acid or Li-Lon
Battery Voltage Range (V)40-60
Max. Charge Current (A)120130200220250280
Max. Discharge Current (A)120130200220250280
Charging Curve3 Stages/Equalization
External Temperature SensorOptional
Charging Strategy for Li-Ion BatterySelf-Adaption to BMS
PV String Input
Max. DC Input Power (W)7,5009,00012,00015,00018,00020,000
PV Input Voltage (V)650(160~800)
MPPT Range (V)200~700
Full Load DC Voltage Range (V)260~650
Start-up Voltage (V)160
PV Input Current (A)17+1717+1717+1726+1726+1726+17
Max. PV Isc (A)20+2020+2020+2034+2034+2034+20
No. of MPPT Trackers2
No. of Strings per MPPT Trackers1+11+11+12+12+12+1
AC Output
Rated AC Output and UPS Power (W)5,0006,0008,00010,00012,00014,000
Max. AC Output Power (W)6,0007,2009,60012,00013,20015,400
Peak PoWer(off grid)2 times of rated power, 10s1.8 times of rated power, 10s
AC Output Rated Current (A)7.6/7.39.1/8.712.1/11.615.2/14.518.2/17.421.1/20.3
Max. AC Current (A)11.4/10.913.6/1318.2/17.422.7/21.727.3/26.127.6/26.4
Max. Continuous AC Passthrough (A)303030505050
Power Factor0.8 leading to 0.8 lagging
Output Frequency and Voltage (V)50/60Hz, 380/400Vac(Triple phase)
Grid TypeThree phase
Current Harmonic DistortionTHD<3%(Linear load<1.5%)
Efficiency
Max. Efficiency97.90%
Euro Efficiency96.90%
MPPT Efficiency99.90%
Protection
IntegratedPV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation
Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection
PV Arc Fault DetectionOptional
Output Over Voltage ProtectionDC Type II/AC Type III
Certifications and Standards
Grid RegulationCEI 0-21, VDE-AR-N 4105, NRS 097, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699,C10-11
Safety RegulationIEC/EN62109-1, IEC/EN62109-2
EMCIEC/EN 61000-6-1,IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4
General Data
Operating Temperature Range (℃)-45~60,>45 Derating
CoolingSmart Cooling
Noise (dB)≤45
Communication with BMSRS485, CAN
Weight (kg)384042444445
Dimensions (mm)510Wx630Hx290D
Protection DegreeIP65
Installation StyleWall-mounted